Subject: Object reference not found errors occur if a new sequence is created and calibrations exist

Symptoms
Object reference not found errors occur if a new sequence is created and calibrations exist

1. Create a new sequence

2. Create a default calibration.

3. Create a new sequence - object reference not found errors occur

 

Causes
This is caused by a bug in EPSON RC+ 6.0.

Remedy
After creating one or more calibrations, save, then restart RC+.


Status
This problem was fixed in EPSON RC+ v6.1.0.